CompanyContactsITEN
Menu

Products

Categories

Control Units

PN Mas

Main unit of the system, contains the program of the system. Equipped with a display for configuring the system and setting user parameters. Through the BUS PICnet communicates with the modules at a maximum speed of 62.500 baud. Data logger function. Astronomic watch. Automatic summer / winter time changeover. MODBUS RTU serial communication port (RS232 or RS485) or TCP / IP. Integrated web server option for remote web control.

PN Easy

Home automation unit, complete with 8 relay outputs and 16 inputs (digital or NTC probe).
230V supply voltage and TA input for single-phase load control. Integrated network port and bus connection up to 4 or 12 slave modules. Integrated web server option for remote web control.

PN Lighton

Light controller, complete with 8 relay outputs and 16 digital inputs. 230V supply voltage and DALI output for control of 64 lamps. Integrated network port and bus connection up to 4 or 12 slave modules. HTML configuration page preloaded on the integrated web server.

Input Modules

PN 4i

Module with four digital inputs in direct voltage. The inputs are opto-isolated and referred to a common voltage that can be independent from the supply one.

PN 8i

Module with eight digital inputs in both direct and alternating voltage. The inputs are opto-isolated and referred to a common voltage that can be independent from the
supply one.

PN 8ibil

Module with eight digital inputs with single / double impedance balance line to detect cable cutting and possible tampering with the command point.

PN 16i

Module with sixteen digital input in both direct and alternating voltage. The inputs are optically isolated and referred to a common voltage which can be independent from the power supply voltage.

PN 4iw

Module with 4 digital inputs for round box. Opto-isolated inputs. Prepared for direct connection with the fruits of any commercial series.

PN 8iw

Module with 8 digital inputs for box 503. Opto-isolated inputs. Prepared for direct connection with the fruits of any commercial series.

PN Ad

The module manages two analog inputs in 0-5V either 0-10V voltage or 4-20 mA current, which can be acquired in differential or single ended mode.

Output modules

PN 8ot

Module with 8 relay outputs for controlling valves and contactors.
The outputs are referred to a common supply voltage that may be independent from the system one.
2A @ 250V resistive relays.

PN 4or

Module with 4 digital relay outputs.
The outputs are referred to a common supply voltage that may be independent from the system one.
16A @ 250V resistive relays.

PN 8or

Module with 8 digital relay outputs.
The outputs are referred to a common supply voltage that may be independent from the system one.
16A @ 250V resistive relays.

PN DA

The module manages two analog outputs in 0-5V or 0-10V voltage.
Both quantities refer to the supply voltage of the system.

Mixed modules

PN 2i2o

2 IN / 2 OUT mixed module.
The inputs are opto-isolated and referred to the system supply voltage.
The outputs are referable to a common external voltage independent of the supply voltage.
Changeover relay with 8A @ 250V resistive.

PN 4i4o

4 IN / 4 OUT mixed module.
The inputs are opto-isolated and referred to the system supply voltage.
The outputs are referable to a common external voltage independent of the supply voltage.
Changeover relays with 8A @ 250V resistive.

PN 8i8o

8 IN / 8 OUT mixed module.
The inputs are opto-isolated and referred to the system supply voltage.
The outputs are referable to a common external voltage independent of the supply voltage.
16A @ 250V resistive relays.

PN 2i2ow

2 IN / 2 OUT mixed module.
Opto-isolated inputs.
Prepared for direct connection with the fruits of any commercial series.
Changeover relays with 8A @ 250V resistive.

PN 4i4ow

2 IN / 2 OUT mixed module.
Opto-isolated inputs.
Prepared for direct connection with the fruits of any commercial series.
Changeover relays with 8A @ 250V resistive.

PN 8iwl

Slave module with 8 opto-isolated digital inputs and 8 digital outputs for connecting external buttons and LEDs.

PN 4i2oa

Mixed module for the management of two independent analog ignition groups. It has four optoisolated digital inputs, two 0-10V outputs for regulation and two relay outputs for ON / OFF control. 12A @ 250V resistive relays.

PN Bar1i1o

Smart plug for rail duct. It has a digital entrance and a relay output that allows the management of one ignition with the same wiring as a common branch plug.

PN Bar2i2o

Smart plug for rail duct. It has two digital inputs and two relay outputs to allow the management of two ignitions or the control of a motorized window with the same wiring of a common branch plug.

Analog modules

PN 4O4A

The module features four 0-10V analog regulation outputs and four relay outputs for ON/OFF control. 8A@250V resistive relays.

PN 4i2oa

Mixed module for the management of two independent analog ignition groups. It has four optoisolated digital inputs, two 0-10V outputs for regulation and two relay outputs for ON / OFF control. 12A @ 250V resistive relays.

PN 4O4A

Il modulo dispone di quattro uscite analogiche 0-10V di regolazione e quattro uscite relè per il controllo ON/OFF.

Relè da 8A@250V resistivi.

PN DA

The module manages two analog outputs in 0-5V or 0-10V voltage.
Both quantities refer to the supply voltage of the system.

PN AD

The module manages two analog inputs in 0-5V either 0-10V voltage or 4-20 mA current, which can be acquired in differential or single ended mode.

Lighting control

PN Lighton

Light controller, complete with 8 relay outputs and 16 digital inputs. 230V supply voltage and DALI output for control of 64 lamps. Integrated network port and bus connection up to 4 or 12 slave modules. HTML configuration page preloaded on the integrated web server.

PN Dali

Protocol converter module that allows connection to the PICnet bus of luminaires with a standard DALI interface.
The module allows the control of 64 lamps. For each lamp the standard commands are available. The module provides direct supply voltage to the DALI bus section.

PN Dali2

Protocol converter module that allows connection to the PICnet bus of luminaires with a standard DALI interface. The module allows the control of 64 lamps. For each lamp the standard commands are available. The module provides direct supply voltage to the DALI bus section.

PN Dmx

Protocol converter module that allows connection to the PICnet bus of elements equipped with connection port to DMX standard, normally used in scenography for light scenarios management (e.g. RGB LED lights, motorized lights, etc.). It can handle up to 64 DMX channels. Also available in built-in version 503.

PN Led

Controller module for 4 channels RGBW constant voltage led strips. Maximum current 2A per channel. Manages up to 2 5m led strips.

PN Dim

Module for independent direct management of two dimmable resistive loads (e.g., incandescent lamps) equipped with four independent digital inputs.

PN 4i2oa

Mixed module for the management of two independent analog ignition groups. It has four optoisolated digital inputs, two 0-10V outputs for regulation and two relay outputs for ON / OFF control. 12A @ 250V resistive relays.

PN Pwm

Led strip control module.
12-24V constant supply voltage from external supply voltage.
Maximum current 5A.

PN Dim1

Single-channel module for direct management of dimmable loads up to 600W resistive.

PN Rgb

Module for LED systems control with dimmable power supply for the realization of chromatic scenarios. The module has 4 independent analog outputs for bright regulation of the 3 RGB sources and 1 white source. It also has a relay output for the ON-OFF command of the controlled device.

PN Lux

The module allows the control of the ambient brightness and is equipped with a wide-spectrum linear sensor.
It has two auxiliary opto-isolated digital inputs.

PN SPL

Sensor module for brightness and presence.
Prepared for false ceiling installation, the module is used in automatic artificial lighting control systems and guarantees the required illumination value.
The presence sensor allows automatic timed shutdown in case of absence of personnel in the room.

Thermoregulation and air treatment

PL DIGITERM

The PL DIGITERM device is a digital thermostat module, an end-device of the LoRa network. The device integrates a temperature probe, 5 relay outputs and 4 digital inputs for autonomous room thermoregulation control, both in heating and cooling. LoRa communication with the local PN LORA concentrator. 230Vac power supply.

PN DIGITERM EXT METAL 6P

Thermostat module with solid aluminum finish. Allows you to regulate the room temperature both in heating and cooling. It has 6 buttons for temperature and scenario control. Integrated temperature probe. Connects directly to the room control unit. Available with integrated PIR. Rectangular or square buttons. Installation in vertical 504 box.

PN DIGITERM EXT METAL 4P

Thermostat module with solid machined aluminum finish.
Allows you to adjust the room temperature for both heating and cooling. It has 6 buttons for temperature and scenario control. Integrated temperature sensor. Connects directly to the room control unit. Available with integrated PIR. Rectangular or square buttons. Installation in 503 vertical box.

PN DIGITERM METAL

Room control module. Allows complete thermoregulation and room management. Fan coil speed selection, window/door contact input and bathroom pull cord. Dual room/bathroom temperature probe. (Probes to be purchased separately).

PN Temp

Module for the measurement of four values of ambient temperature detected by four PN NTC probes.
The module has two opto-isolated digital inputs and two relays for the user control (valve, pump) according to the temperature detected by the first two probes, without engaging others system outputs.

PN Clima

The module allows the regulation of centralized heating systems with or without domestic hot water production. It has four opto-isolated inputs, four relay outputs and three analog inputs for NTC probe.
4A @ 250V resistive relays.

PN Uta

Product suitable for the control of air treatment units (UTA) in complete configuration equipped with heating, cooling, humidification, dehumidification, filtering and air recovery stages. Display for alarms and measures. User interface for direct setting of adjustment parameters.

PN CAL

Thermal energy and domestic hot water consumption metering module. The module features a display for viewing measured quantities and setting measurement parameters, 2 analog inputs for PT100 or PT1000 probes, 2 optoisolated digital inputs for volumetric counters, 2 relay outputs, and 2 configurable optoisolated inputs. The module can also operate in stand-alone mode.

PN Heat

Eight relay output module and sixteen inputs (digital or NTC probe). 230V power supply and TA input for single-phase load control, suitable for the control of electrical thermoregulation systems.

PN Fan

Product suitable for piloting 2-pipe and 3-speed fan coils
in the tertiary sector (offices, shops, schools, hospitals, etc.). It has 3 fan coil relay outputs, bypass solenoid valve relay outputs, NTC PV probe input and 3 digital inputs.
(Probe to be purchased separately)

PN 4i2o2pt

The module has four opto-isolated digital inputs, two relay outputs and two analog inputs for two or three wire PT100 probes.
Changeover relays with 8A @ 250V resistive.
Version for PT1000 available on request.
(Probes to be purchased separately)

PN 8PT

The module features 8 analog inputs for two-wire or three-wire PT100 probes.
PT1000 version available upon request.
(Probes to be purchased separately)

PN SPLIT W

Module for the control of air conditioning systems with internal units with direct expansion (split).
The module has a high emission IR transmitter that is able to reproduce the commands available from remote controller and thus ensure remote control of units that normally only have one IR remote controller.

PN DTERM V

Tempered glass thermostat module, touch technology that allows you to adjust the room temperature in both heating and cooling modes. Automatic or manual operation. Auxiliary input for window contact. Integrated temperature and humidity sensor.

PN Dterm

Thermostat module with 3 relay outputs for fan-coil or solenoid valves that allows to control the room temperature both in heating and in cooling mode. Operation in automatic or manual mode. Auxiliar input for window contact. Equipped with internal temperature probe.

PN Dterma

Thermostat module for inverter fan-coil (0-10V) that allows to control the room temperature both in heating and in cooling mode. Relay output for bypass valve. Operation in automatic or manual mode. Auxiliar input for window contact. Equipped with internal temperature probe.

PN Term

Module for the control of the room temperature equipped with temperature probe and potentiometer for regulation. It has a relay output and two opto-isolated digital inputs. 2A @ 24V resistive relays.

PN Irtx

Infrared transmitter module for the control of devices equipped with IR receiver. Mainly used in the home and hotel sector to control indoor unit devices of air conditioning systems.
The particular patented technology allows to control different devices that could in no other way be controlled centrally.

PN Humi

Analog input module for relative humidity and room temperature measurements complete with optoisolated digital input and auxiliary relay output. Dew point calculation.
2A @ 24V resistive relay.

PN Tempw

Input module for room temperature probes.
The module allows transmission via the PICnet bus of four temperature values detected by four NTCT PV probes (to be purchased separately). The module has two opto-isolated digital inputs and two relays for the user control (valve, pump) according to the temperature detected by the first two probes, without engaging others system outputs.

PN Digiterm Pro

Room control module equipped with control panel. Customizable graphics. It has 16 relay outputs 4A, 2 analog outputs 0-10V, 3 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately).

PN Digiterm

Hotel automation module that allows a complete thermoregulation and room management.
Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately)

PN Digiterm Pro V

Room control module equipped with glass touch control panel. Customizable graphics. It has 16 relay outputs 4A, 3 analog outputs0-10V, 2 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately)

PN Digiterm V

Hotel automation module equipped with glass touch control panel. Customizable graphics. Allows complete thermoregulation and room management. Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately).

PN Split

Room control module with split piloting systems.
The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PN Split V

Room control module with split systems control, equipped with glass touch control panel. Customizable graphics. The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PV Ntc

High precision NTC sensor.
The failure of the temperature sensor or of its connections or the ambient temperature below 5 ° or above 40 °, causes a 'Thermal alarm' on the control module.
Available in free installation version (PP NTC).

PL DTERM

Il dispositivo PL DTERM è un modulo termostato digitale, end-device della rete LoRa. Il dispositivo integra una sonda di temperatura, 4 uscite a relè e 2 ingressi digitali per il controllo autonomo della termoregolazione della stanza, sia in riscaldamento che raffrescamento. Comunicazione LoRa con il
concentratore PN LORA di zona. Alimentazione a 230Vac.

PT100

3-wire PT100 probe in class 'A' precision, suitable for ambient temperature measurement in the industrial applications.
Equipped with anodised aluminium finned tip and IP65 ABS box with cable gland.

PL TEMP

The PL TEMP device is a LoRa network end-device, equipped with a temperature and humidity probe. LoRa communication with the local PN LORA concentrator. Powered by AAx2 batteries.

Air quality

PN Qualitair Pro

The module measures the air quality and is available in two versions. The PN AIR PRO LITE version detects the values of volatile organic compounds VOC, carbon dioxide CO2 and ozone O3 present in the environment, the PN AIR PRO version detects the values of volatile organic compounds VOC, carbon dioxide CO2, ozone O3 and particulate matter PM10, PM2.5 and PM1 present in the environment. In the presence of UV-C sanitizing lamps, the measurement of the ozone concentration O3 indicates the status of the sanitization in progress. Supplied in a wall mounting box.

PN Qualitair Plus

The module measures the air quality by detecting the values of volatile organic compounds VOC, CO2 carbon dioxide and PM10, PM2.5 and PM1 particles present in the environment. It allows to activate the air recirculation when the minimum thresholds of ambient air quality are reached. Supplied in a wall mounting box.

PN Qualitair

The module measures the air quality by detecting the values of volatile organic compounds VOC and CO2 carbon dioxide present in the environment, allowing the recirculation of air to be activated when the minimum environmental air quality thresholds are reached. Supplied in a wall mounting box.

touch screen/User interface

PN Glass

Input slave module. The module has a glass front, black or white colored with 6 touch-sensitive buttons with LED light signaling.
Automatic peripheral proximity lighting.

PN Touch 4

User interface terminal built-in in 506E box with resistive touch screen. The module connects directly to the PICNet bus occupying only one address.
3.5' LED backlit screen.
Graphics resolution 320 x 240 256k colors.
8Mb non-volatile user memory.

PC Touch

Recessed PC Win based touch terminal. Mounted on satin aluminum chassis. It has a user interface with a resistive touch screen. Active matrix color TFT screen. Available in 10 'and 15' versions.

PN Bed

Module for bedside control, has eight buttons on the front and allows the management of eight different functions.
Each button is equipped with LEDs for checking the operating status.
User-customizable graphics.

PN Bed V

Module to control the room from the bedside touch glass, has six buttons on the front and allows the management of six different functions. Each button is backlit for checking the operating status. User-customizable graphics.

PN Pan

The module has eight buttons on the front and allows the management of eight different functions.
Each button is equipped with LEDs to check the status of operation.
User customizable graphics.

PN Pan Ind

The module has an eight-button membrane keyboard with reporting LEDs. Degree of protection IP44. .
Suitable for industrial applications.
User customizable graphics.

PN Digiterm

Hotel automation module that allows a complete thermoregulation and room management.
Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately)

PN Digiterm V

Hotel automation module equipped with glass touch control panel. Customizable graphics. Allows complete thermoregulation and room management. Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately).

PN Digiterm Pro

Room control module equipped with control panel. Customizable graphics. It has 16 relay outputs 4A, 2 analog outputs 0-10V, 3 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately).

PN Digiterm Pro V

Room control module equipped with glass touch control panel. Customizable graphics. It has 16 relay outputs 4A, 3 analog outputs0-10V, 2 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately)

PN Split

Room control module with split piloting systems.
The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PN Split V

Room control module with split systems control, equipped with glass touch control panel. Customizable graphics. The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PN Keyw

Indoor 12 button keypad module in satin stainless steel. It connects directly to the PICnet BUS.

PN Keyb

Vandal-proof 12 button stainless steel keypad module in IP55 metal case. It connects directly to the PICnet BUS.

PN Key Glass

Input slave module. The module has a black or white colored glass front with 12 touch buttons. Proximity automatic peripheral lighting. Customizable graphics.

PN Dterm

Thermostat module with 3 relay outputs for fan-coil or solenoid valves that allows to control the room temperature both in heating and in cooling mode. Operation in automatic or manual mode. Auxiliar input for window contact. Equipped with internal temperature probe.

Hotel automation

PN DIGITERM EXT METAL 6P

Thermostat module with solid aluminum finish. Allows you to regulate the room temperature both in heating and cooling. It has 6 buttons for temperature and scenario control. Integrated temperature probe. Connects directly to the room control unit. Available with integrated PIR. Rectangular or square buttons. Installation in vertical 504 box.

PN DIGITERM EXT METAL 4P

Thermostat module with solid machined aluminum finish.
Allows you to adjust the room temperature for both heating and cooling. It has 6 buttons for temperature and scenario control. Integrated temperature sensor. Connects directly to the room control unit. Available with integrated PIR. Rectangular or square buttons. Installation in 503 vertical box.

PN DIGITERM METAL

Room control module. Allows complete thermoregulation and room management. Fan coil speed selection, window/door contact input and bathroom pull cord. Dual room/bathroom temperature probe. (Probes to be purchased separately).

PN BADGE METAL S

Badge reader with aluminum finish, machined from solid. Access control via transponder cards for hotel applications. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Available for 502 box.

PN BIN PRO METAL S

Smart badge holder for hotel applications with aluminum finish, machined from solid. The PN BIN PRO METAL model allows reading the inserted card code, enabling the implementation of more advanced room control functions. Complete with intermittent signal light when the card is removed. Available for 502 box.

PN PAN METAL S

Smart keypad with aluminum finish, machined from solid. Allows the creation of freely definable room control scenarios. Equipped with backlight LEDs and button identification. Available with integrated PIR. Rectangular or square buttons. Available for 502 box or round box.

PN BEDLIGHT METAL S

Bedside lighting panel with integrated PIR motion sensor. The device detects guest movement and activates the integrated nocturnal bedside lighting. Aluminum finish, machined from solid. Available for round box or 502 box.

PN DIGITERM METAL

Room control module. Allows complete thermoregulation and room management. Fan coil speed selection, window/door contact input and bathroom pull cord. Dual room/bathroom temperature probe. (Probes to be purchased separately)

PN BADGE METAL R

Badge reader with aluminum finish, machined from solid. Access control via transponder cards for hotel applications. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Available for 503 box.

PN BIN PRO METAL R

Smart badge holder for hotel applications with aluminum finish, machined from solid. The PN BIN PRO METAL model allows reading the inserted card code, enabling the implementation of more advanced room control functions. Complete with intermittent signal light when the card is removed. Rectangular or square buttons. Available for 503 box.

PN PAN METAL R

Smart keypad with aluminum finish, machined from solid. Allows the creation of freely definable room control scenarios. Equipped with backlight LEDs and button identification. Available with integrated PIR. Rectangular or square buttons. Available for 503 box.

PN BEDLIGHT METAL R

Bedside lighting panel with integrated PIR motion sensor. The device detects guest movement and activates the integrated nocturnal bedside lighting. Aluminum finish, machined from solid. Available for 503 box.

PN BED METAL

Smart keypad with aluminum finish, machined from solid. Equipped with 6 buttons, allows the creation of freely definable room control scenarios. Equipped with backlight LEDs and button identification. Proximity sensor. Integrated USB-C charging port. Available with integrated PIR. Rectangular or square buttons. Available for 504 box.

PN PAN P METAL

Smart keypad with aluminum finish, machined from solid. Equipped with 4 buttons, allows the creation of freely definable room control scenarios. Equipped with backlight LEDs and button identification. Proximity sensor. Integrated Berger-type socket. Available with integrated PIR. Rectangular or square buttons. Available for 504 box.

PN PAN H METAL

Smart keypad with aluminum finish, machined from solid. Allows the creation of freely definable room control scenarios. Equipped with backlight LEDs and button identification. Features an integrated temperature and humidity sensor. Available with integrated PIR. Rectangular or square buttons. Available for 503 or 504 box.

PN Digiterm Pro V

Room control module equipped with glass touch control panel. Customizable graphics. It has 16 relay outputs 4A, 3 analog outputs0-10V, 2 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately)

PN Digiterm V

Hotel automation module equipped with glass touch control panel. Customizable graphics. Allows complete thermoregulation and room management. Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately).

PN Split V

Room control module with split systems control, equipped with glass touch control panel. Customizable graphics. The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PN Badge V

Glass reader for access control using transponder cards for hotel applications. Customizable graphics.
The module connects directly to PN DIGITERM or PN SPLIT and does not occupy addresses of the PICnet network. Available for MIFARE technology.

PN Badge LV

Large glass reader for access control using transponder cards for hotel applications. Customizable graphics, shows the room number. The module connects directly to PN DIGITERM or PN SPLIT and does not occupy addresses of the PICnet network. Available for MIFARE technology.

PN QR CODE

Tempered glass reader for access control via QR code for hotel applications. Customizable graphics. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Automatic reading with proximity sensor.

PN Bin V

Smart glass badge pocket for hotel applications. Discriminates the presence of a transponder badge from other types of cards. Customizable graphics.
Complete with intermittent signaling light with card off. Available for MIFARE technology.

PN Bed V

Module to control the room from the bedside touch glass, has six buttons on the front and allows the management of six different functions. Each button is backlit for checking the operating status. User-customizable graphics.

PN Touch 4

User interface terminal built-in in 506E box with resistive touch screen. The module connects directly to the PICNet bus occupying only one address.
3.5' LED backlit screen.
Graphics resolution 320 x 240 256k colors.
8Mb non-volatile user memory.

PN Blt

Bluetooth device connection module. Audio player that allows the customer, through any device equipped with a Bluetooth communication interface, to connect and play their own audio streaming in the room. Bluetooth Class 2 device.

PN Digiterm Pro

Room control module equipped with control panel. Customizable graphics. It has 16 relay outputs 4A, 2 analog outputs 0-10V, 3 inputs for NTC probe and 14 digital inputs. It autonomously manages the secondary room PICnet bus. (Probes to be purchased separately).

PN Digiterm

Hotel automation module that allows a complete thermoregulation and room management.
Fan coil speed selection, window / door contact input and bathroom alarm cord.
Room / bathroom double temperature probe. (Probes to be purchased separately)

PN Split

Room control module with split piloting systems.
The module allows thermoregulation and complete management of the room automation.
It has a high-power infrared fruit transmitter for remote control of split units that normally have only one IR remote controller. (Probes to be purchased separately)

PN Badge D

Access control module for hotel applications. The module is a badge reader with transponder technology.
The module connects directly to the PN DIGITERM and does not occupy addresses of the PICnet network.
Available for TITAN or MIFARE technology.

PN Bin

Smart built-in badge holder module.
Identifies the presence of a transponder badge. Equipped with intermittent signal light. Available for TITAN or MIFARE technology.

PN Bin Pro

Smart built-in badge holder module prepared for direct connection to the PN DIGITERM module.
Unlike the PN BIN model, the PN BIN PRO model allows the reading of the card code allowing the implementation of more advanced camera control functions.
Available for MIFARE technology.

PN Badge E

Access control module for hotel applications. The module is a badge reader with transponder technology. It has three signaling LEDs, three relay outputs, two digital inputs and an input for NTC probe. 2A @ 24V resistive relays. Available for MIFARE technology.

PN Bed

Module for bedside control, has eight buttons on the front and allows the management of eight different functions.
Each button is equipped with LEDs for checking the operating status.
User-customizable graphics.

PN Digilite

The module allows thermoregulation and complete management room automation except for access control. It consists of a DIN rail module (3m) for connections with the equipment and the room users.
(Probes to be purchased separately)

PN Keyb

Vandal-proof 12 button stainless steel keypad module in IP55 metal case. It connects directly to the PICnet BUS.

PN Keyw

Indoor 12 button keypad module in satin stainless steel. It connects directly to the PICnet BUS.

PN Key Glass

Input slave module. The module has a black or white colored glass front with 12 touch buttons. Proximity automatic peripheral lighting. Customizable graphics.

PN BADGE KEY

Access control module for general applications. The module is a badge reader with transponder technology and features a 12-button brushed aluminum indoor keypad. It connects directly to the PICnet BUS. Installation in a vertical 506 box.

PV Tpo

Smart badge holder for hotel applications in simplified room automation.
Discriminates the presence of a transponder badge from other types of cards. Complete with intermittent signaling light with card off. It has a front button for the stepper command of the relay output dedicated to the camera lighting.

PN 2i2oh

Module with 2 inputs and 2 relay outputs for controlling the room power supply inserting a badge card in the PV TPO reader, the fancoil and reporting the bathroom tie-rod alarm. Dedicated to Hotel Revamping interventions for simplified room automation.

PN Temph

Complete simplified room automation module. Complete room thermoregulation without the need to replace the existing room thermostat. Possibility to set maximum and minimum temperature values ​​that can be set by the customer and vacant or free room values Room power control and bathroom tie-rod alarm reporting.

PN Badge Prg

The module is a programmer for badge cards with technology transponder.
Supplied in a table container.
Available for TITAN or MIFARE technology.

PL BIN

Badge holder pocket for guest presence detection in hotels. Wall-mounted installation, powered by AAx2 batteries.

PL PIR

Wireless LoRa presence sensor module. Under-ceiling installation, LoRa communication with the local PN LORA concentrator. Powered by AAx2 batteries.

Hotel Manager

Hotel supervision software through the PICnet bus system. The supervision provides an overview of all the rooms and the detail of the selected room. The overall view for each room shows the salient information relating to each room. Any supervision pages of common areas are integrated into the software.

Badge

ISO standard format white PVC card for transponder reader, in TITAN or MIFARE technology. On request the card can be supplied with custom graphics.
The badge is also available in a keychain format.
Magnetic stripe application on request.

Hotel Automation Web

WEB based hotel supervision software. The supervision provides a simple interface for the overall vision of all the rooms and the detail of the selected room. All badge management, check-in and check-out activities and access control of the common areas are managed. Any supervision pages of common areas are integrated into the software. It allows management of the structure even remotely, multi-reception and multi-user.

PN EV CHARGE

Server-based software for managing and controlling electric vehicle charging stations and devices communicating on the OCPP protocol.

The software enables complete supervision and management of electric vehicle charging stations; communication with the charging stations occurs via the standard OCPP (Open Charge Point Protocol), which allows integrated control of charging stations from different manufacturers. In facilities such as hotels, rest areas, supermarkets, companies, and public or private entities, it allows autonomous management of electric vehicle charging stations, eliminating dependence on cloud-based applications from charging station manufacturers.

Room call system

PN Rsa

Module dedicated to room call systems. Installed in the rooms, it allows the management of alarm reset, doctor call and call transfer with indication of the calling room number. Glass panel in aseptic glass allows complete cleaning and possibility of installation in sanitary environments.

PN 4i4o

4 IN / 4 OUT mixed module.
The inputs are opto-isolated and referred to the system supply voltage.
The outputs are referable to a common external voltage independent of the supply voltage.
Changeover relays with 8A @ 250V resistive.

PN 8i8o

8 IN / 8 OUT mixed module.
The inputs are opto-isolated and referred to the system supply voltage.
The outputs are referable to a common external voltage independent of the supply voltage.
16A @ 250V resistive relays.

PN 2i2ow

2 IN / 2 OUT mixed module.
Opto-isolated inputs.
Prepared for direct connection with the fruits of any commercial series.
Changeover relays with 8A @ 250V resistive.

PN 4i4ow

2 IN / 2 OUT mixed module.
Opto-isolated inputs.
Prepared for direct connection with the fruits of any commercial series.
Changeover relays with 8A @ 250V resistive.

PN Vis

Numerical display module
The module allows alphanumeric visualisation on a 3 digits display with high intensity red LEDs.
It is equipped with an alarm buzzer output and one entry for the buzzer silence.
Supplied in a 504 wall box.

PN Vis 2

The module allows alphanumeric visualisation on a six high-intensity red LED digits display. Especially indicated in call systems for alarms signalling. Suitable for wall installation and guarantees excellent distance legibility. It is equipped with an alarm buzzer output and one entry for the buzzer silence

PN Vis 3

The module allows alphanumeric visualisation on a three high-intensity red LED digits display. Especially indicated in hospital or nursering home call systems for the alarm signalling. Suitable for wall installation in the single-sided or for flag installation in the double-sided version. Font Size h=10cm.

PN Vis 4

The module allows alphanumeric visualisation on a four high-intensity red LED digits display. Especially indicated in hospital or nursering home call systems for the alarm signalling. Suitable for wall installation in the single-sided or for flag installation in the double-sided version. Font Size h=10cm. Integrated clock functionality

PV Call 2

Two-command push-button panel, one for requesting medical and service personnel for patient wards of hospitals, clinics and nursing homes and one for switching on the light. Degree of protection IP 67.

PV Cord

Pull button, connects to a clean contact input of the room control unit.

PV Lamp

Specula fuoriporta led a 4 colori. Funzionalità luce notturna e luce di emergenza.

PN PDS

The PN PDS device is the wireless communication hub for the Presence Detection System. It communicates via radio with pressure sensors installed on hospital beds and connects directly to the PICnet communication and power bus. Also available in a version with contact outputs.

PV BEDSENSE

The PV BEDSENSE device is a battery-powered wireless communication unit to which one or more pressure detection strips, installed under the mattress in hospital beds (code PVBED STRIP, to be purchased separately), are connected. In Presence Detection systems, one PV BEDSENSE unit is provided for each bed. All devices are associated with the local PN PDS concentrator module, with which they communicate wirelessly.

Access control

PN BADGE METAL S

Badge reader with aluminum finish, machined from solid. Access control via transponder cards for hotel applications. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Available for 502 box.

PN BIN PRO METAL S

Smart badge holder for hotel applications with aluminum finish, machined from solid. The PN BIN PRO METAL model allows reading the inserted card code, enabling the implementation of more advanced room control functions. Complete with intermittent signal light when the card is removed. Available for 502 box.

PN BADGE METAL R

Badge reader with aluminum finish, machined from solid. Access control via transponder cards for hotel applications. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Available for 503 box.

PN BIN PRO METAL R

Smart badge holder for hotel applications with aluminum finish, machined from solid. The PN BIN PRO METAL model allows reading the inserted card code, enabling the implementation of more advanced room control functions. Complete with intermittent signal light when the card is removed. Rectangular or square buttons. Available for 503 box.

PN Biokey

The PN BIOKEY module is a device for access control with biometric fingerprint recognition technology (max 100 fingerprints).

PN Badge H

Access control module for hotel applications.
The module is a badge reader with transponder technology. It has three signaling LEDs, a call button and two relay outputs. 2A @ 24V resistive relays.
Available for TITAN technology.

PN Badge G

Access control module for general applications.
The module is a badge reader with transponder technology. It has two signaling LEDs and two relay outputs.
2A @ 24V resistive relays.
Available for TITAN or MIFARE technology.

PN Badge F

Access control module for general applications.
The module is a badge reader with transponder technology. It has two signaling LEDs and two relay outputs.
2A @ 24V resistive relays.
Available for TITAN technology.

PN Key Glass

Input slave module. The module has a black or white colored glass front with 12 touch buttons. Proximity automatic peripheral lighting. Customizable graphics.

PN Keyb

Vandal-proof 12 button stainless steel keypad module in IP55 metal case. It connects directly to the PICnet BUS.

PN Keyw

Indoor 12 button keypad module in satin stainless steel. It connects directly to the PICnet BUS.

PN QR CODE

Tempered glass reader for access control via QR code for hotel applications. Customizable graphics. The module connects directly to the PN DIGITERM or PN SPLIT and does not occupy PICnet network addresses. Automatic reading with proximity sensor.

PN Badge Prg

The module is a programmer for badge cards with technology transponder.
Supplied in a table container.
Available for TITAN or MIFARE technology.

Badge

ISO standard format white PVC card for transponder reader, in TITAN or MIFARE technology. On request the card can be supplied with custom graphics.
The badge is also available in a keychain format.
Magnetic stripe application on request.

Badge Manager

Access control software. The user can view the transits and access in each zone with the indication of the card number, the person's identification, the group to which he belongs, the time, the date and the zone of the transit. Through a simple interface it is possible to set the various operating options such as the division into zones of the system, the enabling of the cards, the setting of the groups to which they belong and the activation time bands.

Display

PN Dis

Message display module with variable fields via backlit display. Like the Master module, the PNDIS module has an alarm buzzer and a relay output that can be activated to display a user message or an alarm.

PN Vis

Numerical display module
The module allows alphanumeric visualisation on a 3 digits display with high intensity red LEDs.
It is equipped with an alarm buzzer output and one entry for the buzzer silence.
Supplied in a 504 wall box.

PN Vis 2

The module allows alphanumeric visualisation on a six high-intensity red LED digits display. Especially indicated in call systems for alarms signalling. Suitable for wall installation and guarantees excellent distance legibility. It is equipped with an alarm buzzer output and one entry for the buzzer silence

PN Vis 3

The module allows alphanumeric visualisation on a three high-intensity red LED digits display. Especially indicated in hospital or nursering home call systems for the alarm signalling. Suitable for wall installation in the single-sided or for flag installation in the double-sided version. Font Size h=10cm.

PN Vis 4

The module allows alphanumeric visualisation on a four high-intensity red LED digits display. Especially indicated in hospital or nursering home call systems for the alarm signalling. Suitable for wall installation in the single-sided or for flag installation in the double-sided version. Font Size h=10cm. Integrated clock functionality

Interfaces

PN Bridge

PICnet - MODBUS RTU bus conversion module on serial port RS-232 or RS-485.

PN Com

PICnet - RS 232 bus conversion module. It allows the interfacing of the system to external devices equipped of serial communication port. Drivers for the management of control panels (audio, anti-intrusion, fire prevention) of the major manufacturers are available.

PN Eth

PICnet - Ethernet bus conversion module. It allows the interfacing of the system to external devices equipped of data network port. Drivers for the management of control panels (audio, anti-intrusion, fire prevention) of the major manufacturers are available.

PN B2b

With this device it is possible to create PICnet bus networks or allow communication between different buses. This architecture allows the automation of high complexity buildings without the need the PC supervision to support the operating logic. Also available in a built-in container.

Measurement modules

PN Lux

The module allows the control of the ambient brightness and is equipped with a wide-spectrum linear sensor. It has two auxiliary opto-isolated digital inputs.

PN Spl

Sensor module for brightness and presence. Prepared for false ceiling installation, the module is used in automatic artificial lighting control systems and guarantees the required illumination value. The presence sensor allows automatic timed shutdown in case of absence of personnel in the room.

PN Temp

Module for the measurement of four values of ambient temperature detected by four PN NTC probes. The module has two opto-isolated digital inputs and two relays for the user control (valve, pump) according to the temperature detected by the first two probes, without engaging others system outputs.

PN Humi

Analog input module for relative humidity and room temperature measurements complete with optoisolated digital input and auxiliary relay output. Dew point calculation. 2A @ 24V resistive relay.

PN CAL

Thermal energy and domestic hot water consumption metering module. The module features a display for viewing measured quantities and setting measurement parameters, 2 analog inputs for PT100 or PT1000 probes, 2 optoisolated digital inputs for volumetric counters, 2 relay outputs, and 2 configurable optoisolated inputs. The module can also operate in stand-alone mode.

PN Tempw

Input module for room temperature probes. The module allows transmission via the PICnet bus of four temperature values detected by four NTCT PV probes (to be purchased separately). The module has two opto-isolated digital inputs and two relays for the user control (valve, pump) according to the temperature detected by the first two probes, without engaging others system outputs.

PN Meteo

Outdoor weather station IP55.
Composed of anemometer, luxmeter and rain sensor. Anemometer: 0-50 km / h resolution 0.05 m/s.
Luxmeter: 100-25,000 lux resolution 100 lux; 10-2.500 lux resolution 10 lux

PN Cvm3

DIN rail module that allows the interface to the bus PICnet of the multifunction measuring instrument for electric quantities, produced by ASITA mod. CVM-MINI CVM / M / RS4C2 (to be purchased separately) - cod. PV MLT.

PN Cvm1

DIN rail module that allows the interface to the bus PICnet of the multifunction measuring instrument for electric quantities, produced by ASITA mod. CVM-1D-RS485-C (to be purchased separately) - cod. PV MLM.

PV NTC

High precision NTC sensor.
The failure of the temperature sensor or of its connections or the ambient temperature below 5 ° or above 40 °, causes a 'Thermal alarm' on the control module.
Available in free installation version (PP NTC).

PV PT100

3-wire PT100 probe in class 'A' precision, suitable for ambient temperature measurement in the industrial applications.
Equipped with anodised aluminium finned tip and IP65 ABS box with cable gland.

PN CAL

Thermal energy and domestic hot water consumption metering module. The module features a display for viewing measured quantities and setting measurement parameters, 2 analog inputs for PT100 or PT1000 probes, 2 optoisolated digital inputs for volumetric counters, 2 relay outputs, and 2 configurable optoisolated inputs. The module can also operate in stand-alone mode.

Software

Simply

Simplified programming software, without the need to know the syntax and programming rules of the PN MAS control unit. he software consists of a guided procedure that accompanies the user in defining the modules present in the system and in their configuration and programming through a simple user interface. At the end of the procedure, the software automatically generates the user program to be downloaded on the PN MAS module.

PN Link

Complete programming software for programming and setting up the PICnet system. Simple system utilities allow low-level control for maintenance, system installation and even remote control of the system. It is in fact possible to connect to the master module of the system and remotely carry out all the control operations, control of the users and updating the program.

PN Link Pro

Software for applications with plant supervision through a graphical interface that is completely configurable and adaptable to the user application. The software supports various types of connection to the control module: via TCP / IP, RS232 and USB.

PN Link Web

Software for applications with remote plant supervision through a fully configurable WEB interface that can be adapted to the user application. The software is installed on a PC or a web server which can be consulted remotely from any device via any browser.

Hotel Manager

Hotel supervision software through the PICnet bus system. The supervision provides an overview of all the rooms and the detail of the selected room. The overall view for each room shows the salient information relating to each room. Any supervision pages of common areas are integrated into the software.

Hotel Manager Web

WEB based hotel supervision software. The supervision provides a simple interface for the overall vision of all the rooms and the detail of the selected room. All badge management, check-in and check-out activities and access control of the common areas are managed. Any supervision pages of common areas are integrated into the software. It allows management of the structure even remotely, multi-reception and multi-user.

Badge Manager

Access control software. The user can view the transits and access in each zone with the indication of the card number, the person's identification, the group to which he belongs, the time, the date and the zone of the transit. Through a simple interface it is possible to set the various operating options such as the division into zones of the system, the enabling of the cards, the setting of the groups to which they belong and the activation time bands.

Graph Manager

Web graphic software for data processing and supervision using dynamic graphics. Particularly suitable for energy management, air quality management and thermoregulation applications, for analysis and trends in consumption, temperatures and environmental pollution indicators.

PN SUPERVISOR

Piattaforma software di supervisione multi-impianto multi-Master.
Il software PN SUPERVISOR permette la creazione di una piattaforma di supervisione multi-master, dialogando con un numero indefinito di unità PN MAS connesse in rete.
Il software permette la creazione di dashboard di supervisione multi-impianto.

PN EV CHARGE

Software server-based di gestione e controllo di colonnine e dispositivi di ricarica elettrica comunicanti su protocollo OCPP.
Il software permette la completa supervisione e gestione di stazioni di ricarica elettrica; la comunicazione con le colonnine presenti avviene tramite protocollo standard OCPP (Open Charge Point Protocol) che permette il controllo integrato di colonnine di produttori differenti. In strutture come alberghi, aree di sosta, supermercati, aziende e enti pubblici o privati, permette la gestione autonoma delle stazioni di ricarica elettrica eliminando la dipendenza da applicativi in-cloud dei produttori di colonnine.

Remote control

PN Mas

Main unit of the system, contains the program of the system. Equipped with a display for configuring the system and setting user parameters. Through the BUS PICnet communicates with the modules at a maximum speed of 62.500 baud. Data logger function. Astronomic watch. Automatic summer / winter time changeover. MODBUS RTU serial communication port (RS232 or RS485) or TCP / IP. Integrated web server option for remote web control.

PN Easy

Home automation unit, complete with 8 relay outputs and 16 inputs (digital or NTC probe). 230V supply voltage and TA input for single-phase load control. Integrated network port and bus connection up to 4 or 12 slave modules. Integrated web server option for remote web control.

PN Lighton

Light controller, complete with 8 relay outputs and 16 digital inputs. 230V supply voltage and DALI output for control of 64 lamps. Integrated network port and bus connection up to 4 or 12 slave modules. HTML configuration page preloaded on the integrated web server.

Webserver

Device for professional control from any remote location, via connection and Internet browser. Supervision available from any platform (tablet, smartphone, PC, etc.) without any need to install dedicated sw. Simultaneous multi-user and multidevice supervision management.

PV App Plus

App server that through the OpenHAB App allows to supervise the entire PICnet automation system through PC, smartphone and tablet. It allows the native integration with all the devices supported by OpenHab platform. Recommended for complex applications or in the presence of graphic data processing software.

PV App

App server that through the OpenHAB App allows to supervise the entire PICnet automation system through PC, smartphone and tablet. It allows the native integration with all the devices supported by OpenHab platform.

PN Gsm

PICnet bus module for the transmission of SMS messages. Through this device it is possible to send and receive variable SMS messages, in order to allow a first level of supervision and remote control of the system from any one mobile phone.

PV Sms

The module is suitable for remote control of small systems, it offers the possibility to send programmable text messages to pre-set telephone numbers and to activate outputs with SMS commands. The Clip function allows to activate an output after the recognition of a specific calling number. It has 4 digital inputs, 2 relay outputs and an input for NTC probe.

Accessories

PN Rep

The module allows the isolated connection between different bus sections. Used to regenerate the bus signal on very long distances or to isolate high-noise sections.

PV Gsm

The module is connected to the serial service output of a master module, allows remote connection to the system via a GSM line. All functions normally performed for system maintenance and control are performed remotely and transparently to the user.

PV Sms

The module is suitable for remote control of small systems, it offers the possibility to send programmable text messages to pre-set telephone numbers and to activate outputs with SMS commands. The Clip function allows to activate an output after the recognition of a specific calling number. It has 4 digital inputs, 2 relay outputs and an input for NTC probe.

PV Ntc

High precision NTC sensor. The failure of the temperature sensor or of its connections or the ambient temperature below 5 ° or above 40 °, causes a 'Thermal alarm' on the control module. Available in free installation version (PP NTC).

PV Pt100

3-wire PT100 probe in class 'A' precision, suitable for ambient temperature measurement in the industrial applications. Equipped with anodised aluminium finned tip and IP65 ABS box with cable gland.

Badge

ISO standard format white PVC card for transponder reader, in TITAN or MIFARE technology. On request the card can be supplied with custom graphics. The badge is also available in a keychain format. Magnetic stripe application on request.

Apn

AC / DC switching power supplies in DIN rail or from DIN rail back panel. Equipped with overload, internal overtemperature and short circuit protection.

PN Bus

BUS cable with very low parasitic capacity, recommended in particularly for large and complex plants, in order to guarantee the maximum transmission speed. Composed of 2x0.5mm² twisted conductors for bus signal + 2x1.0mm² for system power supply. Available in 200m spools

PN Backup

Module used in critical applications where continuity of service is essential, it allows to switch system operation to a back-up master module in case of failure of the main master module. The module switches all bus signals and serial communication, ensuring continuity of operation, including supervision.

Audio series

PN Dabrep

Repeater / splitter and power injector. It allows to split a line and to recondition the signal re-establishing the correct impedance.

PN Blt

Bluetooth device connection module. Audio player that allows the customer, through any device equipped with a Bluetooth communication interface, to connect and play their own audio streaming in the room. Bluetooth Class 2 device.

PN Linein

Module with active microphone input, Linein input and Lineout output for stereo headphones. It allows to send messages and communication, the reproduction of analog stereo sources e local listening by headphones. 3.5mm microphone jack and linein/headphone jack.

PN Dab

Class D audio amplifier slave module, capable of managing speakers connected in BTL (Bridge Tied Load) mode. DSP processor 32bit for extremely clear audio, Dynamic range control. Support for pseudo bass enhancement and virtual 3D effect. Maximum power deliverable 20W RMS.

PN Matrix

Digital audio matrix with 8 independent DAB outputs and 4 input channels.

PN Media

Professional quality multi-source audio player with ethernet port for web interface management and DABnet system controller.

PN Play

Multi-source audio player with DABnet system controller. Available inputs: TOSLINK entrance S / P-DIF input Streaming from USB (virtual speaker)

PN Playbox

Multi-source audio player with DABnet system controller. Music streaming from Spotify, SoundCloud, Google Music, Podcasts (with iTunes, gPodder), MP3 / OGG / FLAC / AAC, Webradio (with TuneIn, Dirble), Subsonic, Soma FM. Remote control through the APP MusicBox interface.

Pn Dabrep

Repeater / splitter and power injector.
It allows to split a line and to recondition the signal re-establishing the correct impedance.

PN Linein

Module with active microphone input, Linein input and Lineout output for stereo headphones. It allows to send messages and communication, the reproduction of analog stereo sources e local listening by headphones. 3.5mm microphone jack and linein/headphone jack.

PN Trm

Line terminator.

PN Mux

Signal multiplexer, propagates into output one of the two DAB input signals.

PV Mic

Table base with ON-OFF flexible switch with cardioid condenser electret microphone terminated with 5 meters of cable equipped with XLR male connector and 2 conductors for priority activation (din-don).

Wireless series

PN LORA

The PN LORA device is the concentrator of the LoRa device network. Each PN LORA unit can manage up to 30 peripheral devices. The device is available both with a communication port for the PICnet bus and with an integrated network port, to be managed regardless of the presence of a PICnet system.

PL 2I2O

2 IN / 2 OUT Wireless LoRa Mixed Module. Inputs are opto-isolated. Outputs are 16A@250V resistive changeover relays. 230Vac power supply.

PL TEMP

The PL TEMP device is a LoRa network end-device, equipped with a temperature and humidity probe. LoRa communication with the local PN LORA concentrator. Powered by AAx2 batteries.

PL DTERM

The PL DTERM device is a digital thermostat module, an end-device of the LoRa network. The device integrates a temperature sensor, 4 relay outputs and 2 digital inputs for autonomous room temperature control, both in heating and cooling modes. LoRa communication with the PN LORA area concentrator. 230Vac power supply.

PL PIR

Wireless LoRa presence sensor module. Under-ceiling installation, LoRa communication with the local PN LORA concentrator. Powered by AAx2 batteries.

PL COM

The PL COM module is a Modbus converter for the integration of electrical measurement and analysis instruments. 230Vac power supply.

PL CONTACT

The PL CONTACT module is a wireless LoRa magnetic sensor for doors/windows. It is able to detect the opening and closing of doors and windows and report it to the PN LORA area concentrator. AAx2 battery powered.

PL BIN

Badge holder pocket for guest presence detection in hotels. Wall-mounted installation, powered by AAx2 batteries.

PN Zigb

Coordinator module of the ZIGBee® network. This is the device that create and manage the network of modules by communicating with the end-devices that adhere to the wireless network. Each network has a unique identifier that makes it possible to create multiple parallel and separate networks within the same system. A ZIGbee network is a 'mesh' system, i.e. each device is able to repeat the signal to other devices thus allowing to cover large distances or to work reliably even in harsh environments. Available in version for MODBUS and KNX protocol.

PZ Fan1

End-device of the ZIGBnet network for on/off control of valves or fan coils. This module is equipped with a single input for NTC probe and it allows to regulate the room temperature both in heating and in cooling mode autonomously. The only information it requires is the set-point and the current season received from the ZIGBnet network. 230Vac supply voltage.

PZ Fan2

End-device of the ZIGBnet network for the control of 3-speed fan coils with bypass valve. This module is equipped with double input for NTC probe and it allows to regulate the room temperature both in heating and in cooling mode autonomously. 230Vac supply voltage.

PZ Light

End-device of the PN ZIGBnet network for the control of dimmable ballasts. This module has a relay output for on/off power control and a 0-10V analogue output for connection to the ballast control input. 230Vac supply voltage.

PZ 4i4o

This module is a mixed end-device with 4 opto-isolated digital inputs and 4 relay outputs. It has 4 relay outputs for direct supply of power loads. The inputs are all referred to a power supply independent from the supply voltage. 230Vac supply voltage.

PZ Spl

Sensor module for brightness and presence. The module is suitable for ceiling installation and used in automatic lighting control systems in order to guarantee the compliant illuminance value according to natural light variation. 230Vac supply voltage.

PZ Pt100

PT100 probe in precision class 'A' IS suitable for the detection of outdoor ambient temperature or in industrial environments. Equipped with anodised aluminium finned tip and IP65 ABS box with cable gland. Power supply: 2 AA batteries.

PF 20

Two-channel 2-way radio receiver powered by 230V 50 / 60Hz network extremely compact, with OOK superheterodyne receiver 434 MHz ASK with high performance and reliability. Anti-interference digital filter to further improve radio performance.

PN Fmtx

Two-channel radio transmitter with 434 MHz based OOK modulation on SAW resonator. Complies with R&TTE 99/05 / CE and RoHS 2011/65/EU, EU REGULATION No. 1907/2006 (THE REACH DIRECTIVE).

PZ Probe

ZIGBee wireless temperature and humidity sensor. It is able to detect in real time the data relating to the temperature, humidity and atmospheric pressure of the environment and to communicate them to the PICnet concentrator. CR2032 battery.

PZ Contact

ZIGBee wireless door / window sensor. It is able to detect the opening and closing of doors and windows and to report it to the PICnet concentrator. CR1632 battery.

PZ Valve

ZIGBee wireless thermostatic valve. It is able to manage the thermoregulation of radiators and room radiators through the PICnet system. AAx2 battery.

crossmenu